Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arch Cardiovasc Dis ; 111(4): 285-296, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29422386

RESUMO

BACKGROUND: Global longitudinal strain (GLS) has several sources of variation. Strain multilayer tracking is a new tool that has not yet been validated in clinical practice. AIM: The purpose of this study was to investigate intervendor variability when measuring multilayer strain in patients receiving chemotherapy for cancer. METHODS: Patients receiving chemotherapy for cancer, who were referred for echocardiography, were included prospectively. First, the same operator performed two-dimensional echocardiography on each patient using the Vivid E9™ (General Electric, Fairfield, CT, USA) and the ACUSON SC2000™ (Siemens, Munich, Germany) ultrasound systems. Second, we assessed myocardial deformation by using their respective speckle-tracking software. Third, we compared absolute values of GLS for the two vendors in each apical view (four-, three- and two-chamber) and for each layer (endocardial, mid-myocardial and epicardial). RESULTS: Eighty patients with cancer were included prospectively between February and June 2015. For a given vendor, GLS values decreased from the endocardial layer to the epicardial layer. For a given view, GLS values obtained with the ACUSON SC2000 platform were systematically lower than those obtained with the Vivid E9 platform (P<0.0001). We observed a significant difference between the two platforms, irrespective of the layer, interlayer gradient or chamber view considered (P<0.0001). CONCLUSIONS: There was poor agreement for layer-specific strain evaluation between the Vivid E9 and ACUSON SC2000 platforms, using their dedicated software for strain multilayer assessment. These results suggest that, in clinical practice, the same system and software from the same vendor should be used for longitudinal follow-up.


Assuntos
Antineoplásicos/efeitos adversos , Ecocardiografia/instrumentação , Cardiopatias/diagnóstico por imagem , Contração Miocárdica/efeitos dos fármacos , Neoplasias/tratamento farmacológico , Adulto , Fenômenos Biomecânicos , Cardiotoxicidade , Desenho de Equipamento , Feminino , Cardiopatias/induzido quimicamente , Cardiopatias/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Software , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...